We have updated our data protection policies based on new GDPR act. See Details
 You are viewing products available in Nedco all division. Change
  • Store Locator
  • Join our newsletter
  • Catalogues
  • Schneider Configurator
  • Schneider Training
  • Canadian Products
  • all
  • 


Changing the pickup branch can affect product availability.

Try refining your search.
Edit Logo

Uploaded logo will be displayed on header

Upload Logo

Uploaded logo will be displayed on header

Drop your file to upload
Nedco Webshop
Drag to Reposition

 Drag & drop or Browse

 Upload photo
Uploading...

Zoom

Left Right
 Delete Logo
Last Modified By   * on  

Are you sure you want to delete the photo?

Nedco Webshop
Nedco Webshop
0 – try another search
  •  
    Log In
    Register

    Get your BEST experience!

    Your email is missing an '@'

    Forgot Username
    Caps lock is on
    Forgot Password

    Register your account

  • Fast Order
    Upload a product file
  •   Cart 0
 Back
  • Browse Products
    • View All Categories
    • View All Brands
  •  Sign In

  • View All Categories
  • View All Brands
  • Fast Order
  • Branch locator
  • About Us
    • About:
    • About Nedco
    • Nedco Careers
    • History
    • News
  • Suppliers
    • Top Brands
    • View All Brands
  • Digital Tools
    • Our Tools:
    • Catalogues
    • Easy Cart Builder
    • Fast Order
    • Job List
    • Nedco Mobile App
    • Quotes
    • Supplier Tools:
    • ABB Configurator
    • IPEX Calculator
    • LEDVANCE (SYLVANIA) Lighting Layout Tool
    • Schneider Configurator
  • Solutions & Services
    • Solutions:
    • Datacom Solutions
    • Energy Solutions
    • First Nations Energy Savings
    • Lighting Solutions
    • Sustainable Selection
    • Wire & Cable
    • Services:
    • 24/7 Locker Pickup
    • Text Your Branch
  • feedback New
    • Loading promotions. Please wait

  • sell Promotions
    • Loading promotions. Please wait

  • savings Clearance
    • Loading promotions. Please wait

Select billing account

Current account :

 

Change billing account

Select your project(s)
Choose Delivery Address
 Changing the branch may affect the stock of all items. Some items may no longer have stock for purchase.
  • Browse
  • Enter New Address
Map content here
Choose your Nedco division
Update Cart?

Changing division would affect availability and pricing of products in your cart.

This website uses cookies to improve your online experience. By accepting you agree to allow us store cookies on your computer. Learn More

This website uses cookies to improve your online experience. By accepting you agree to allow us store cookies on your computer. Learn More

Changing your ship-to location may impact your product pricing and availability.

Do you want to proceed with this change?

Confirm Add to Cart

You have a fixed quote in your cart. If you add this product to cart, all quoted products will be removed. Please complete the order for your quote first and add this product to the cart afterwards.

Or click the button below to replace your current cart with this product.

  1. Home
  2. Distribution
  3. Industrial Distribution
  4. Disconnects
  5. Rotary Disconnect Switch Accessories
  6. MGA36600
  • 
Product videos
Product images
MGA36600 3P 600V 600A I-LINE MCCB MGA36600 3P 600V 600A I-LINE MCCB
 Previous
 Next
Rotary Disconnect Switch Accessories - MGA36600 3P 600V 600A I-LINE MCCB - MGA36600
MGA36600 3P 600V 600A I-LINE MCCB
SCHNEIDERlogo
SCHNEIDER

MGA36600 3P 600V 600A I-LINE MCCB

Product code: 
SCHMGA36600
Mfr Number: 
MGA36600

Contact your local branch to check product availability.

Look up branches

Log In

to view your price and product availability



Contact your sales representative to confirm availability.

Available Lengths
 EA

Min: 1 EA , Multiple  1 EA

View Alternative
 Item already in cart


Contact your sales representative to confirm availability.

 Add to cart
  

Technical Documents



Technical Documents

 Catalog Page
 Cut Sheet
 Owners Manual
 Submittal
Technical Documents
 Back

Technical Documents

 Catalog Page
 Cut Sheet
 Owners Manual
 Submittal

Product Details



Product Details

MGA36600 3P 600V 600A I-LINE MCCB
Circuit breaker, PowerPacT M, 600A, 3 pole, 600VAC, 18kA, I-Line, ET 1.0, 80%, ABC

PowerPact M-frame molded case circuit breakers provide improved performance and a compact solution for applications up to 800A. They complement the existing PowerPact P- and R-frame circuit breakers and replace the traditional MA/MH circuit breakers with a smaller footprint and competitive cost. PowerPact M-frame molded case circuit breakers are available in 300, 350, 400, 450, 500, 600, 700, and 800A ratings. PowerPact M-frame molded case circuit breakers have built-in electronic trip unit type ET 1.0 provides better accuracy than standard thermal-magnetic trip units. The ET 1.0 trip unit cannot be field replaced, nor does it allow adjustment of the trip point setting. (It is considered an electronic equivalent of a thermal-magnetic circuit breaker.) They also have fIxed long-time and adjustable instantaneous protection (2 to 10 times nominal ampere rating) is standard. Powerpact M-Frame breakers have the same dimensions, common mounting, bussing, cabling and door cut-out as PowerPact P-frame circuit breakers. This PowerPact M, circuit breaker has a rated current of 600A and a rated operational current of 600VAC and is an I-Line mounted breaker. This 3-pole breaker has a breaking capacity of 18kA@600VAC with an 80 % continuous current rating. This breaker complies to UL listed, IEC & CSA standards. This product has an electronic ET 1.0 trip unit trechnology and a magnetic tripping current of 1200-6000A. Dimensions for this product are 12.86 in (H),8.27 in (W), 5.77 in (D). This product comes with an 18 month warranty.

Technical Specifications



Technical Specifications

Rotary Disconnect Switch Accessories
Product Name PowerPact M
Pkg UOM EA
Mfr UNSPSC 39121601
Application POWER DISTRIBUTION
Catalog Number MGA36600
Pkg Height 10.5
Pkg Length 18
Mfr Fullname SQUARE D/TELEMECANIQUE
Pkg Weight 28.86
Pkg Type PK
Approval UL, CSA
Mfrcode SQD
Pkg Qty 1
Pkg Width 12
Current Rating 600 AMPERE
Used On CLASS 612/661 I-LINE[R] PANELBOARD/SWITCHBOARD
Pkg Weight UOM LB
Trip Setting 1200 TO 6000 AMPERE
Voltage Rating 240/480/600 VAC AT 50/60 HZ, 480 VAC STAR/277 VAC AT 50/60 HZ, 600 VAC STAR/347 VAC AT 50/60 HZ (UL/CSA/NOM) 240/415 VAC AT 50/60 HZ (IEC)
Interrupting Rating 65 KILOAMPERE AT 240 VAC, 35 KILOAMPERE AT 480 VAC OR 480 VAC STAR/277 VAC, 18 KILOAMPERE AT 600 VAC OR 600 VAC STAR/347 VAC (UL/CSA/NOM) 35 KILOAMPERE AT 415 VAC, 50 KILOAMPERE AT 240 VAC (IEC)
Number Of Poles 3
China Rohs Regulation Product out of China RoHS scope. Substance declaration for your information
Long Time Pick-Up Adjustment Range 300...800 A
Circularity Profile ENVEOLI2206030EN
Continuous Current Rating 80%
Tightening Torque 50-50 N.m 95-240 mm² 3 x AWG 3/0...3 x 500 kcmil)
Environmental Disclosure ENVPEP2206030EN
Range PowerPact
Length 25 mm
[Uimp] Rated Impulse Withstand Voltage 8 kV IEC 60947-2
Device Application distribution
Product Or Component Type circuit breaker
Magnetic Tripping Current 1200-6000 A
[Ue] Rated Operational Voltage 600 V AC 50/60 Hz UL 489
Breaking Capacity Code G
Ambient Air Temperature For Storage -50-85 °C
Ambient Air Temperature For Operation -25-70 °C
Product Certifications UL
Breaking Capacity AIR 65 kA 240 V AC 50/60 Hz UL 489
Carbon Footprint (Kg Co2 Eq, Total Life Cycle) 2882.270815
Electrical Connection I-Line connection, line
 
Height 12.86 in
[Ui] Rated Insulation Voltage 750 V IEC 60947-2
Pollution Degree 3 IEC 60947-1
Mounting Height 9 in
Wire Stripping Length 25 mm
Poles Description 3P
Trip Unit Technology electronic, basic, ET 1.0,
Pvc Free Yes
Mounting Support bracket
Quality Labels CE
Local Signalling 1 trip indicator green)
Rohs Exemption Information Yes
Standards UL
Control Type operating handle
Depth 8.05 in
Packaging Without Single Use Plastic Yes
Scip Number 21500b23-9fd3-49c7-8372-6c1a79b6c751
Weight 29 lbs
[In] Rated Current 600-600 A
Width 8.27 in
Number Of Slots 2 auxiliary switch OF plug-in)
Mounting Mode I-Line bracket)
Quantity Per Set 1
Circuit Breaker Application HACR rated
Take-Back No
Terminal Identifier AL800M23K
Awg Gauge 3 x AWG 3/0...3 x 500 kcmil aluminum/copper
Operating Altitude < 2000 m without derating
Trip Unit Name ET 1.0
Packaging Made With Recycled Cardboard Yes
Eu Rohs Directive Compliant with Exemptions
Net Weight 29 lb(US)
Reach Regulation Reference contains Substances of Very High Concern above the threshold
Ip Degree Of Protection IP40
Colour black
[Ics] Rated Service Breaking Capacity 25 kA 240 V AC 50/60 Hz IEC 60947-2
Suitability For Isolation yes IEC 60947-2
Mercury Free Yes
Network Frequency 50/60 Hz
Utilisation Category category A
Share this product
Please check the checkbox below to move along

F-Gas (Fluorinated gases) government regulations specify that a limited number of products can be sold in the European Union that contain F-gases which have been linked to climate change.

We encourage you to find products that meet your needs and do not contain these gases.

Subscribe to our newsletter and get access to sales, demos, training and more!
Products
  • Electrical Distribution
  • Electrical Wire & Cable
  • Heating & Ventilation
  • Motor Control & Automation
  • Conduit, Tray & Fittings
  • Electrical Boxes & Enclosures
  • Lamps, Ballast & Accessories
  • All Product Categories
Resources
  • FAQ
  • Web Manager
  • Supplier Resources
  • Green Programs
Downloads
  • Credit Application
  • Mobile App
General Info
  • About us
  • Accessibility
  • AODA
  • Contact us
  • Careers
Support
  • Click & Pick
  • Delivery
  • Privacy
  • Return Policy
  • Modern Slavery Policy
  • Modern Slavery Report
  • Cookie Settings
Linkedin Facebook Twitter instagram youtube
app store app store
©2025 Rexel
| Terms & Conditions
| Privacy Policy
|International Sites open_in_new

A Rexel Group Company
©2025 Rexel www.rexel.ca

rexel global logo
Cookies Management

Please Choose your cookie settings

If Cookies are disabled, some features on the website may not work properly.More details found here inData protection