Changing the pickup branch can affect product availability.
Uploaded logo will be displayed on header
Uploaded logo will be displayed on header
Drag & drop or Browse
Upload photoAre you sure you want to delete the photo?
Loading promotions. Please wait
Loading promotions. Please wait
Loading promotions. Please wait
Changing division would affect availability and pricing of products in your cart.
This website uses cookies to improve your online experience. By accepting you agree to allow us store cookies on your computer. Learn More
This website uses cookies to improve your online experience. By accepting you agree to allow us store cookies on your computer. Learn More
Changing your ship-to location may impact your product pricing and availability.
Do you want to proceed with this change?
You have a fixed quote in your cart. If you add this product to cart, all quoted products will be removed. Please complete the order for your quote first and add this product to the cart afterwards.
Or click the button below to replace your current cart with this product.
Contact your local branch to check product availability.
to view your price and product availability
Contact your sales representative to confirm availability.
Min: 1 EA , Multiple 1 EA
MCCB (Moulded Case Circuit Breakers) Up To 600A | |
Current Rating | 70 AMPERE |
---|---|
Pkg Width | 6.3 |
Voltage Rating | 240 VAC AT 50/60 HZ, 480 VAC STAR/277 VAC AT 50/60 HZ, 480 VAC AT 50/60 HZ, 600 VAC STAR/347 VAC AT 50/60 HZ, 600 VAC AT 50/60 HZ (UL/CSA/NOM) 240/415 VAC AT 50/60 HZ (IEC) 250 VDC |
Approval | UL, CSA, CE |
Number Of Poles | 2 |
Pkg Length | 7.8 |
Additional Information | APPLICABLE STANDARD W-C-375B/GEN |
Interrupting Rating | 25 KILOAMPERE AT 240 VAC, 18 KILOAMPERE AT 480 VAC STAR/277 VAC OR 480 VAC, 14 KILOAMPERE AT 600 VAC STAR/347 VAC OR 600 VAC (UL/CSA/NOM) 25 KILOAMPERE AT 240 VAC, 18 KILOAMPERE AT 415 VAC (IEC) 250 VDC |
Catalog Number | HDL26070 |
Mfr Fullname | SQUARE D/TELEMECANIQUE |
Mfrcode | SQD |
Pkg Weight UOM | LB |
Pkg Weight | 3 |
Product Name | PowerPact H |
Terminal Type | LINE LUG, LOAD LUG |
Pkg UOM | EA |
Pkg Qty | 1 |
Pkg Height | 7.2 |
Pkg Type | PK |
Size | 2.74 INCH W X 4.36 INCH D X 6.4 INCH H |
Frame Type | H |
Type | MOLDED CASE, THERMAL MAGNETIC |
Maximum AC Voltage Rating | 600 V |
Mfr UNSPSC | 39121601 |
Maximum DC Voltage Rating | 250 V |
Pvc Free | Yes |
Colour | black |
Ambient Air Temperature For Storage | -50-85 °C |
Width | 104 mm |
Device Application | distribution |
Continuous Current Rating | 80% |
Utilisation Category | category A |
Communication Interface | Modbus |
Local Signalling | switched off (OFF) 1 trip indicator green) |
Weight | 2.2 kg |
Country of Origin | Mexico |
Circuit Breaker Application | HACR rated |
Net Weight | 2.2 kg |
Take-Back | No |
[Uimp] Rated Impulse Withstand Voltage | 8 kV IEC 60947-2 |
Mounting Support | lug |
Ambient Air Temperature For Operation | -25-70 °C |
Suitability For Isolation | yes IEC 60947-2 |
Breaking Capacity Code | D |
---|---|
Network Frequency | 50/60 Hz |
Breaking Capacity | 25 kA 240 V AC 50/60 Hz UL 489 |
Depth | 86 mm |
Wire Stripping Length | 16 mm |
Quality Labels | CE |
Terminal Identifier | AL150HD |
[In] Rated Current | 70-70 A |
Pollution Degree | 3 IEC 60947-1 |
Height | 163 mm |
[Ui] Rated Insulation Voltage | 750 V IEC 60947-2 |
Length | 16 mm |
Range | PowerPact |
Magnetic Hold Current | 800 A |
Number Of Slots | 2 auxiliary switch OF plug-in) |
Packaging Made With Recycled Cardboard | Yes |
Operating Altitude | < 2000 m without derating |
Protected Poles Description | 2t |
Product Certifications | UL |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
Quantity Per Set | 1 |
Mercury Free | Yes |
Mounting Mode | unit mount lug) |
Electrical Connection | lugs, line |
Packaging Without Single Use Plastic | No |
Magnetic Tripping Current | 1450-1450 A |
Control Type | toggle |
Eu Rohs Directive | Compliant with Exemptions |
Circularity Profile | ENVEOLI2206027EN |
China Rohs Regulation | Product out of China RoHS scope. Substance declaration for your information |
Carbon Footprint (Kg Co2 Eq, Total Life Cycle) | 320.0417875 |
Poles Description | 2P |
Product Or Component Type | circuit breaker |
Trip Unit Technology | thermal-magnetic |
Tightening Torque | 5-5 N.m 2.5-6 mm² AWG 14...AWG 10) |
Ip Degree Of Protection | front cover IP40 IEC 60529 |
Standards | UL |
[Ue] Rated Operational Voltage | 690 V AC 50/60 Hz IEC 60947-3 |
Environmental Disclosure | ENVPEP2206027EN |
Awg Gauge | AWG 14...AWG 3/0 aluminum/copper terminal |
[Ics] Rated Service Breaking Capacity | 25 kA 220/240 V AC 50/60 Hz IEC 60947-2 |
Rohs Exemption Information | Yes |