Changing the pickup branch can affect product availability.
Uploaded logo will be displayed on header
Uploaded logo will be displayed on header
Drag & drop or Browse
Upload photoAre you sure you want to delete the photo?
Loading promotions. Please wait
Loading promotions. Please wait
Loading promotions. Please wait
Changing division would affect availability and pricing of products in your cart.
This website uses cookies to improve your online experience. By accepting you agree to allow us store cookies on your computer. Learn More
This website uses cookies to improve your online experience. By accepting you agree to allow us store cookies on your computer. Learn More
Changing your ship-to location may impact your product pricing and availability.
Do you want to proceed with this change?
You have a fixed quote in your cart. If you add this product to cart, all quoted products will be removed. Please complete the order for your quote first and add this product to the cart afterwards.
Or click the button below to replace your current cart with this product.
Contact your local branch to check product availability.
to view your price and product availability
Contact your sales representative to confirm availability.
Min: 1 EA , Multiple 1 EA
Main Lug Only | |
| Terminal Type | LINE LUG, LOAD LUG |
|---|---|
| Type | MOLDED CASE, THERMAL MAGNETIC |
| Additional Information | APPLICABLE STANDARD W-C-375B/GEN |
| Pkg Type | PK |
| Maximum AC Voltage Rating | 600 V |
| Mfrcode | SQD |
| Number of Poles | 2 |
| Catalog Number | MGL26600 |
| Pkg Weight | 27.7 |
| Product Name | PowerPact M |
| Pkg Weight UOM | LB |
| Mfr UNSPSC | 39121601 |
| Pkg Qty | 1 |
| Size | 8.27 INCH W X 8.05 INCH D X 12.86 INCH H |
| Interrupting Rating | 65 KILOAMPERE AT 240 VAC, 35 KILOAMPERE AT 480 VAC STAR/277 VAC OR 480 VAC, 18 KILOAMPERE AT 600 VAC STAR/347 VAC OR 600 VAC (UL/CSA/NOM) 50 KILOAMPERE AT 240 VAC, 35 KILOAMPERE AT 415 VAC (IEC) |
| Approval | UL, CSA, CE |
| Frame Type | M |
| Mfr Fullname | SQUARE D/TELEMECANIQUE |
| Current Rating | 600 AMPERE |
| Voltage Rating | 240 VAC AT 50/60 HZ, 480 VAC STAR/277 VAC AT 50/60 HZ, 480 VAC AT 50/60 HZ, 600 VAC STAR/347 VAC AT 50/60 HZ, 600 VAC AT 50/60 HZ (UL/CSA/NOM) 240/415 VAC AT 50/60 HZ (IEC) |
| Pkg UOM | EA |
| Terminal Identifier | AL800M23K |
| Local Signalling | 1 trip indicator green) |
| Ambient Air Temperature For Operation | -25-70 °C |
| [In] Rated Current | 600-600 A |
| Pollution Degree | 3 IEC 60947-1 |
| Country of Origin | United States |
| Rohs Exemption Information | Yes |
| Magnetic Tripping Current | 1200-6000 A |
| Packaging Made With Recycled Cardboard | Yes |
| Height | 12.86 in |
| Network Frequency | 50/60 Hz |
| Weight | 29 lbs |
| [Ue] Rated Operational Voltage | 600 V AC 50/60 Hz UL 489 |
| Pvc Free | Yes |
| Suitability For Isolation | yes IEC 60947-2 |
| [Ui] Rated Insulation Voltage | 750 V IEC 60947-2 |
| Ip Degree Of Protection | IP40 |
| Standards | UL |
| Packaging Without Single Use Plastic | Yes |
| Trip Unit Name | ET 1.0 |
| Environmental Disclosure | ENVPEP2206030EN |
|---|---|
| Colour | black |
| Continuous Current Rating | 80% |
| Mounting Support | lug |
| Control Type | operating handle |
| Quality Labels | CE |
| Take-Back | No |
| China Rohs Regulation | Product out of China RoHS scope. Substance declaration for your information |
| Carbon Footprint (Kg Co2 Eq, Total Life Cycle) | 1944.484356 |
| Ambient Air Temperature For Storage | -50-85 °C |
| Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
| Net Weight | 29 lb(US) |
| Tightening Torque | 50-50 N.m 95-240 mm² 3 x AWG 3/0...3 x 500 kcmil) |
| Width | 8.27 in |
| Awg Gauge | 3 x AWG 3/0...3 x 500 kcmil aluminum/copper |
| Long Time Pick-Up Adjustment Range | 300...800 A |
| Range | PowerPact |
| Breaking Capacity | AIR 65 kA 240 V AC 50/60 Hz UL 489 |
| Trip Unit Technology | electronic, basic, ET 1.0, |
| [Ics] Rated Service Breaking Capacity | 25 kA 240 V AC 50/60 Hz IEC 60947-2 |
| Wire Stripping Length | 25 mm |
| Electrical Connection | lugs, load |
| Circuit Breaker Application | HACR rated |
| Eu Rohs Directive | Compliant with Exemptions |
| Device Application | distribution |
| Circularity Profile | ENVEOLI2206030EN |
| Number Of Slots | 2 auxiliary switch OF plug-in) |
| Product Certifications | UL |
| Breaking Capacity Code | G |
| Quantity Per Set | 1 |
| Length | 25 mm |
| Scip Number | 21500b23-9fd3-49c7-8372-6c1a79b6c751 |
| [Uimp] Rated Impulse Withstand Voltage | 8 kV IEC 60947-2 |
| Mercury Free | Yes |
| Product Or Component Type | circuit breaker |
| Operating Altitude | < 2000 m without derating |
| Poles Description | 2P |
| Mounting Mode | unit mount lug) |
| Depth | 8.05 in |
| Utilisation Category | category A |
F-Gas (Fluorinated gases) government regulations specify that a limited number of products can be sold in the European Union that contain F-gases which have been linked to climate change.